Resilience-Focused Server Room Design

Server Room Setup: Precision Cooling & Raised Flooring

We plan server room infrastructure by evaluating heat load, airflow, humidity, power, rack layout and future growth for servers, storage and network equipment.

Automatic Gas Fire Suppression

Fire Detection and Suppression for Server Rooms:
FM200 & NOVEC 1230 Gas Suppression

Fire detection and the appropriate suppression solution should be engineered according to room volume, risk assessment, equipment, detection scenario and applicable technical requirements.

Uninterruptible Power (UPS) & Generator Infrastructure

Plan for Power Continuity:
Redundant (N+1) Online UPS Systems

We plan power-continuity architecture around load, battery runtime and redundancy targets using online double-conversion UPS, PDU, ATS and generator integration where appropriate.

Sensor-Based Environment Monitoring & Biometric Access

Get Instant Mobile Alarms for
Room Temperature and Humidity

Sensor units that send SMS and email notifications in case of temperature rise, flooding, smoke, and unauthorized entry, plus encrypted card/fingerprint door access.

Why Doz Technology Server Room Solutions?

Randomly placed servers overheat and get dusty. We design server rooms that address cooling, fire safety, power resilience, rack infrastructure and monitoring requirements together.

Resilience & Continuity Design

We design appropriate power and cooling redundancy options based on critical load, growth, maintenance and business-continuity targets.

Precision Cooling

We size In-Row / In-Room precision cooling options according to IT heat load, airflow, humidity and redundancy requirements.

FM200 / NOVEC Gas Suppression

We engineer gas suppression and fire-detection systems according to room volume, equipment, risk assessment and applicable technical requirements.

Redundant UPS & Electrical Panels

We plan power continuity and maintenance scenarios for critical IT loads using online UPS, PDU, ATS and appropriate redundancy architecture.

Sensor-Based Environment Tracking

Remotely monitor temperature rise, water leaks, humidity, and door openings; receive instant SMS alerts to your phone during critical threshold breaches.

Server Room Project Team

We execute design, raised floor, epoxy coating, fireproof door, and cabling phases turnkey with our expert engineering staff.

Expert Server Room Services

Data center architecture, precision cooling, FM200 gas suppression, raised floors, and environment monitoring systems.

Raised Floor & Grilles

Anti-static calcium sulfate panels, steel leg structures, and perforated grilles for airflow.

  • Fire-Resistant Anti-Static Surface
  • Hot / Cold Aisle Configuration

Precision Cooling

45-55% humidity and 20-22°C constant temperature guarantee with In-Row and In-Room precision air conditioners.

  • Humidity Monitoring and Control
  • N+1 Auto Redundant AC Operation

FM200 & NOVEC 1230 Suppression

Cross-Zone smoke detection detectors, automatic gas cylinders, and solenoid valve control panels.

  • Harmless Gas for Electronic Devices
  • Auto Damper & Fan Shutdown

Uninterruptible Power (UPS) & PDU

Online On-Grid UPS devices, battery groups, manageable Rack PDU sockets, and bypass panels.

  • Dual Supply (A-B Power) Cabinet Line
  • Smart Battery Monitoring & Auto Generator

Environment Monitoring & Sensors

Central environment tracking software integration with temperature, humidity, water leak, smoke, and voltage sensors.

  • Instant SMS & E-Mail Alarm Notification
  • Live Monitoring via Web & Mobile

Biometric Access Security

Fingerprint, facial recognition, and encrypted steel door lock systems preventing unauthorized entry to the server room.

  • Fire-Resistant Steel Door Systems
  • Entry/Exit Time-Stamped Logging

Server Rack Cabinet & Organization

42U/47U perforated ventilated server cabinets, vertical/horizontal cable organizers, and labeling.

  • Encrypted Cabinet Door Access
  • High Air Permeability Mesh Door

Exploration, Consulting & Revision

Inspection of your aging, overheating, and cluttered server rooms, risk analysis, and modernization report.

  • Free On-Site Exploration Support
  • Thermal & Load Capacity Report